Notification of abstract acceptance
announced via E-mail on July 31st.
Abstract view



Oct. 18 (Thu)  Grand Ballroom 105 Room - SS05 NR
10:10-10:20 [SS 05 NR-04] 
Detection of true aneurysm using high resolution time-of-flight magnetic resonance angiograph (HR-MRA) at 3.0 Tesla: correlation with standard digital subtraction angiography (DSA)
   
Speaker ALEUM LEE (Seoul National University Hospital)
Authors ALEUM LEE,Chulho Sohn,Jihoon Kim,Seunghong Choi,Taejin Yun
Affiliation Seoul National University Hospital
PDF View  SS 05 NR-04.pdf

PDF File View :
PURPOSE:
1. To evaluate accuracy of 3T HR-MRA in detecting aneurysm compared wit conventional MRA (C-MRA)
2. To prove potential diagnostic advantage of HR-MRA using correlation with DSA

MATERIAL AND METHODS:
32 patients with 43 possible aneurysms on C-MRA were underwent 3T HR-MRA and DSA. The protocols of HR-MRA were following:TR 29.0, TE 4.6, matrix 512x512, FOV 20cm, and thickness 0.5mm with 8 channel head coil. Two blinded neuroradiologists reviewed C-MRA and HR-MRA in the detection of aneurysms, independently. For each possible aneurysm, readers recorded the location and their level of confidence with a 3 point scale (0:no, 1:suspicious, and 2:definite aneurysm). 2D or VR-DSA were obtained and used as the standard of reference. The accuracy was calculated in addition to the sensitivity and specificity of HR-MRA compared to C-MRA. In particular, cases with advantage of detection on HR-MRA were evaluated in detail.

RESULTS:
DSA revealed 35 aneurysms in 25 patients and no aneurysm or ID in 8 cases in 7 patients. Multiple aneurysms were 12 cases in 8 patients. On HR-MRA, reviewers exactly detected 40, 37 cases, superior to C-MRA (29, 32 cases). On the lesion-based evaluation, accuracy, sensitivity, and specificity of were 89.5%, 91.5, and 81.3% on HR-MRA and 72.1%, 81.5%, and 31.3% on C-MRA, respectively. Each 3 and 5 suspicious aneurysm on C-MRA were re-categorized as definite aneurysm.

CONCLUSION:
HR-MRA had a high accuracy, sensitivity and specificity for the detection of intracranial aneurysms, comparing C-MRA. In equivocal aneurysm on C-MRA, HR-MRA can be a useful tool and replace DSA.